Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.279
Filtrar
1.
Clin Orthop Surg ; 16(2): 210-216, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562629

RESUMO

Background: As the population ages, the rates of hip diseases and fragility fractures are increasing, making total hip arthroplasty (THA) one of the best methods for treating elderly patients. With the increasing number of THA surgeries and diverse surgical methods, there is a need for standard evaluation protocols. This study aimed to use deep learning algorithms to classify THA videos and evaluate the accuracy of the labelling of these videos. Methods: In our study, we manually annotated 7 phases in THA, including skin incision, broaching, exposure of acetabulum, acetabular reaming, acetabular cup positioning, femoral stem insertion, and skin closure. Within each phase, a second trained annotator marked the beginning and end of instrument usages, such as the skin blade, forceps, Bovie, suction device, suture material, retractor, rasp, femoral stem, acetabular reamer, head trial, and real head. Results: In our study, we utilized YOLOv3 to collect 540 operating images of THA procedures and create a scene annotation model. The results of our study showed relatively high accuracy in the clear classification of surgical techniques such as skin incision and closure, broaching, acetabular reaming, and femoral stem insertion, with a mean average precision (mAP) of 0.75 or higher. Most of the equipment showed good accuracy of mAP 0.7 or higher, except for the suction device, suture material, and retractor. Conclusions: Scene annotation for the instrument and phases in THA using deep learning techniques may provide potentially useful tools for subsequent documentation, assessment of skills, and feedback.


Assuntos
Artroplastia de Quadril , Aprendizado Profundo , Fraturas Ósseas , Prótese de Quadril , Humanos , Idoso , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Fêmur/cirurgia , Estudos Retrospectivos
2.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578350

RESUMO

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
3.
Sci Rep ; 14(1): 8332, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594498

RESUMO

Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems. Patients with symptomatic hip disease who underwent primary THA in the supine position using both AR CT-based and portable AR-based navigation systems simultaneously between October 2021 and July 2023 were included. The primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative CT. The secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (RI) and radiographic anteversion (RA) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. This study included 94 consecutive patients. There were 11 men and 83 women, with a mean age of 68 years. The mean absolute errors of RI were 2.7° ± 2.0° in the AR CT-based and 3.3° ± 2.4° in the portable AR-based navigation system. The mean absolute errors of RA were 2.5° ± 2.1° in the AR CT-based navigation system and 2.3° ± 2.2° in the portable AR-based navigation system. No significant differences were observed in RI or RA of the cup between the two navigation systems (RI: p = 0.706; RA: p = 0.329). No significant factors affected the absolute value of the navigation errors in RI and RA. In conclusion, there were no differences in the accuracy of cup insertion between the AR CT-based and portable AR-based navigation systems.


Assuntos
Artroplastia de Quadril , Realidade Aumentada , Prótese de Quadril , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Idoso , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Cirurgia Assistida por Computador/métodos , Acetábulo/cirurgia
4.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632066

RESUMO

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Masculino , Feminino , Humanos , Idoso , Falha de Prótese , Reoperação , Estudos Retrospectivos , Inteligência Artificial , Seguimentos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Complicações Pós-Operatórias , Luxações Articulares/cirurgia
5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 461-465, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632067

RESUMO

Objective: To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. Methods: The three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results: The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences ( P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=-21.192+0.248×width+0.140×length, and the coefficient of determination R 2=0.857, P<0.001. Conclusion: Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Filme para Raios X , Tomografia Computadorizada por Raios X/métodos
6.
J Orthop Surg Res ; 19(1): 253, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644485

RESUMO

INTRODUCTION: We present a detailed procedure for the robotic-assisted plate osteosynthesis of an anterior acetabular fracture. The purpose of this work was to describe a robotic-assisted minimally invasive technique as a possible method for reducing complications, pain, and hospitalization. Another goal was to present technical recommendations and to assess potential pitfalls and problems of the new surgical approach. METHODS: Surgery was performed in an interdisciplinary setting by an experienced orthopedic surgeon and a urologist. The DaVinci System with standard instruments was used. Reduction was achieved through indirect traction of a pin that was introduced into the femoral neck and direct manipulation via the plate. The plate position and fixation were achieved through 7 additional minimally invasive incisions. RESULTS: The technique has multiple advantages, such as no detachment of the rectus abdominal muscle, a small skin incision, and minimal blood loss. Furthermore, this approach might lower the incidence of hernia formation, infection, and postoperative pain. DISCUSSION: We see the presented technique as a demanding yet progressive and innovative surgical method for treating acetabular fractures with indications for anterior plate fixation. TRIAL REGISTRATION: The study was approved by the local institutional review board (Nr. 248/18).


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Procedimentos Cirúrgicos Robóticos , Humanos , Acetábulo/cirurgia , Acetábulo/lesões , Procedimentos Cirúrgicos Robóticos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Feminino , Adulto
7.
Sci Rep ; 14(1): 9475, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658572

RESUMO

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Assuntos
Osteotomia , Doses de Radiação , Exposição à Radiação , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto Jovem , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Luxação do Quadril/prevenção & controle , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Criança
8.
Med Eng Phys ; 126: 104159, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621833

RESUMO

Generation of polyethylene wear debris and peri­prosthetic bone resorption have been identified as potential causes of acetabular component loosening in Total Hip Arthroplasty. This study was aimed at optimization of a functionally graded porous acetabular component to minimize peri­prosthetic bone resorption and polyethylene liner wear. Porosity levels (porosity values at acetabular rim, and dome) and functional gradation exponents (radial and polar) were considered as the design parameters. The relationship between porosity and elastic properties were obtained from numerical homogenization. The multi-objective optimization was carried out using a non-dominated sorting genetic algorithm integrated with finite element analysis of the hemipelvises subject to various loading conditions of common daily activities. The optimal functionally graded porous designs (OFGPs -1, -2, -3, -4, -5) exhibited less strain-shielding in cancellous bone compared to solid metal-backing. Maximum bone-implant interfacial micromotions (63-68 µm) for OFGPs were found to be close to that of solid metal-backing (66 µm), which might facilitate bone ingrowth. However, OFGPs exhibited an increase in volumetric wear (3-10 %) compared to solid metal-backing. The objective functions were found to be more sensitive to changes in polar gradation exponent than radial gradation exponent, based on the Sobol' method. Considering the common failure mechanisms, OFGP-1, having highly porous acetabular rim and less porous dome, appears to be a better alternative to the solid metal-backing.


Assuntos
Artroplastia de Quadril , Reabsorção Óssea , Prótese de Quadril , Humanos , Porosidade , Acetábulo/cirurgia , Metais , Polietileno , Reabsorção Óssea/cirurgia , Algoritmos , Desenho de Prótese , Falha de Prótese
9.
J Orthop Surg Res ; 19(1): 258, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654343

RESUMO

BACKGROUND: Debates persist over optimal pelvic girdle reconstruction after acetabular tumor resection, with surgeons grappling between modular and 3D-printed hemipelvic endoprostheses. We hypothesize superior outcomes with 3D-printed versions, yet scarce comparative research exists. This study fills the gap, examining biomechanics and clinical results retrospectively. METHODS: From February 2017 to June 2021, we retrospectively assessed 32 patients undergoing en bloc resection for malignant periacetabular tumors at a single institution. PRIMARY OUTCOME: limb function. SECONDARY OUTCOMES: implant precision, hip joint rotation center restoration, prosthesis-bone osteointegration, and complications. Biomechanical characteristics were evaluated through finite element analysis on pelvic defect models. RESULTS: In the 3D-printed group, stress distribution mirrored a normal pelvis, contrasting the modular group with elevated overall stress, unstable transitions, and higher stress peaks. The 3D-printed group exhibited superior functional scores (MSTS: 24.3 ± 1.8 vs. 21.8 ± 2.0, p < 0.05; HHS: 79.8 ± 5.2 vs. 75.3 ± 3.5, p < 0.05). Prosthetic-bone interface osteointegration, measured by T-SMART, favored 3D-printed prostheses, but surgery time (426.2 ± 67.0 vs. 301.7 ± 48.6 min, p < 0.05) and blood loss (2121.1 ± 686.8 vs. 1600.0 ± 505.0 ml, p < 0.05) were higher. CONCLUSIONS: The 3D-printed hemipelvic endoprosthesis offers precise pelvic ring defect matching, superior stress transmission, and function compared to modular endoprostheses. However, complexity, fabrication expertise, and challenging surgical implantation result in prolonged operation times and increased blood loss. A nuanced consideration of functional outcomes, complexity, and patient conditions is crucial for informed treatment decisions. LEVEL OF EVIDENCE: Level III, therapeutic study (Retrospective comparative study).


Assuntos
Acetábulo , Neoplasias Ósseas , Salvamento de Membro , Procedimentos de Cirurgia Plástica , Impressão Tridimensional , Humanos , Estudos Retrospectivos , Feminino , Masculino , Acetábulo/cirurgia , Pessoa de Meia-Idade , Neoplasias Ósseas/cirurgia , Adulto , Fenômenos Biomecânicos , Salvamento de Membro/métodos , Salvamento de Membro/instrumentação , Resultado do Tratamento , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/instrumentação , Desenho de Prótese , Estudos de Coortes , Idoso , Adulto Jovem , Fatores de Tempo
10.
Int J Med Robot ; 20(1): e2615, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536714

RESUMO

BACKGROUND: In Total Hip replacement (THR) surgery, a critical step is to cut an accurate hemisphere into the acetabulum so that the component can be fitted accurately and obtain early stability. This study aims to determine whether burring rather than reaming the acetabulum can achieve greater accuracy in the creation of this hemisphere. METHODS: A preliminary robotic system was developed to demonstrate the feasibility of burring the acetabulum using the Universal Robot (UR10). The study will describe mechanical design, robot trajectory optimisation, control algorithm development, and results from phantom experiments compared with both robotic reaming and conventional reaming. The system was also tested in a cadaver experiment. RESULTS: The proposed robotic burring system can produce a surface in 2 min with an average error of 0.1 and 0.18 mm, when cutting polyurethane bone block #15 and #30, respectively. The performance was better than robotic reaming and conventional hand reaming. CONCLUSION: The proposed robotic burring system outperformed robotic and conventional reaming methods to produce an accurate acetabular cavity. The findings show the potential usage of a robotic-assisted burring in THR for acetabular preparation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos
11.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38541181

RESUMO

Background and Objectives: The objective of this retrospective study was to investigate the association between acetabulum fractures; the mechanism of injury; and variables such as BMI, duration of hospital stay, blood loss, and surgery time. By exploring these factors, we aim to enhance our understanding of them and their impact on the healing process and the subsequent management of pelvic fractures. Materials and Methods: This study included 67 of 136 consecutive patients who were admitted for pelvic ring fracture surgery between 2017 and 2022. The data were collected prospectively at a single trauma center. The inclusion criteria were acetabulum fractures and indications for operative treatment. The exclusion criteria were non-operative treatment for acetabular and pelvic ring fractures, fractures requiring primary total hip arthroplasty (THA), and periprosthetic acetabular fractures. Upon admission, all patients underwent evaluation using X-ray and computed tomography (CT) scans of the pelvis. Results: The present study found no statistically significant differences between the examined groups of patients with pelvic fractures in terms of BMI, surgery duration, length of hospital stay, and blood transfusion. However, two notable findings approached statistical significance. Firstly, patients who experienced a fall from height while sustaining a pelvic fracture required a higher number of blood transfusions (2.3 units) than those with other mechanisms of injury which was close to achieving statistical significance (p = 0.07). Secondly, patients undergoing posterior wall stabilization required a significantly lower number of blood transfusions than those with other specific pelvic injuries (0.33 units per patient), approaching statistical significance (p = 0.056). Conclusions: The findings indicated that factors such as BMI, time of surgery, blood loss, and the duration of hospital stay were not directly correlated with the morphology of acetabular fractures, the presence of additional trauma, or the mechanism of injury. However, in the studied group, the patients whose mechanism of trauma involved falling from height had an increased number of blood transfusions compared to other groups. Moreover, the patients who had surgery due to posterior wall acetabulum fracture had decreased blood transfusions compared to those with other Judet and Letournel types of fractures. Additionally, they had the shortest duration of surgery.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Acetábulo/cirurgia , Estudos Retrospectivos , Índice de Massa Corporal , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Fraturas do Quadril/complicações , Hemorragia/complicações , Hospitais
12.
Bone Joint J ; 106-B(4): 324-335, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555946

RESUMO

Aims: Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods: This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results: There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and leg length (mean 0.6 mm vs 1.4 mm; p < 0.001). Patient-reported outcome measures were comparable between the two groups at baseline and one year. Participants in the RO THA group needed fewer physiotherapy sessions postoperatively (median six (IQR 4.5 to 8) vs eight (IQR 6 to 11; p = 0.005). Conclusion: This RCT suggested that robotic-arm assistance in THA was associated with improved accuracy in restoring the native COR, better preservation of the combined offset, leg length correction, and superior accuracy in achieving the desired acetabular component positioning. Further evaluation through long-term and registry data is necessary to assess whether these findings translate into improved implant survival and functional outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Tomografia Computadorizada por Raios X , Estudos Prospectivos
13.
J Pediatr Orthop ; 44(5): e433-e438, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38454629

RESUMO

BACKGROUND: Traumatic, posterior hip dislocations in the pediatric population are typically managed by closed reduction to achieve a concentric hip joint. The presence of an acetabular "fleck" sign, despite concentric reduction, has been shown to signify significant hip pathology. The purpose of this study was to evaluate the outcomes of open labral repair through a surgical hip dislocation (SHD) in a consecutive series of patients with an acetabular "fleck" sign associated with a traumatic hip dislocation/subluxation. METHODS: A retrospective review of patients between 2008 and 2022 who presented to a single, level 1 pediatric trauma center with a traumatic posterior hip dislocation/subluxation was performed. Patients were included if they had an acetabular "fleck" sign on advanced imaging and underwent open labral repair through SHD. Medical records were reviewed for sex, age, laterality, mechanism of injury (MOI), and associated orthopaedic injuries. The modified Harris hip score (mHHS) was utilized as the primary clinical outcomes measure. Patients were assessed for the presence of heterotopic ossification (HO) and complications, including implant issues, infection, avascular necrosis (AVN), and post-traumatic dysplasia. RESULTS: Twenty-nine patients (23 male, average age: 13.0±2.7 y; range: 5.2 to 17.3) were identified. Eighteen injuries were sports related, 9 caused by motor vehicle accidents, and 1 pedestrian struck. All patients were found to have an acetabular "fleck" sign on CT (26 patients) or MRI (5 patients). Associated injuries included: femoral head fracture (n=6), pelvic ring injury (n=3), ipsilateral femur fracture (n=2), and ipsilateral PCL avulsion (n=1). At the latest follow-up (2.2±1.4 y), all patients had returned to preinjury activity/sport. Three patients developed asymptomatic, grade 1 HO in the greater trochanter region. There was no incidence of AVN. One patient developed post-traumatic acetabular dysplasia due to early triradiate closure. mHHS scores showed excellent outcomes (n=21, 94.9±7.4, range: 81 to 100.1). CONCLUSIONS: The acetabular "fleck" sign indicates a consistent pattern of osteochondral avulsion of the posterior/superior labrum. Restoring native hip anatomy and stability is likely to improve outcomes. SHD with open labral repair in these patients produces excellent clinical outcomes, with no reported cases of AVN. LEVEL OF EVIDENCE: Level IV-therapeutic.


Assuntos
Fraturas do Fêmur , Luxação do Quadril , Humanos , Masculino , Criança , Adolescente , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
14.
Zhongguo Gu Shang ; 37(3): 319-26, 2024 Mar 25.
Artigo em Chinês | MEDLINE | ID: mdl-38515423

RESUMO

Acetabular quadrilateral plate injury has become a hot spot and focus in the field of orthopaedic trauma and pelvic floor function in recent years. Although there are five fracture types,they are all based on fracture morphology,without considering the pulling force of ligaments,joint capsular and muscles. A perfect classification needs to describe the displacement of bone mass in three-dimensional space to better guide reduction and fixation. The seven incision and exposure methods are still the traditional open-eye surgery,and how to protect the criss-crossing vascular neural network and pelvic organs is still the focus. Quadrilateral defect causes dislocation of artificial hip joint,and quantitative evaluation of quadrilateral defect volume and revision techniques are still a hot topic. In this paper,the viewpoints of three-dimensional network structure of acetabular pelvic vascular anatomy,anatomical surgical target channel and fixation anchor point of acetabular fracture reduction are proposed to design new techniques for accurate and minimally invasive surgical operations,in order to realize the requirements of rapid orthopedic rehabilitation.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Acetábulo/cirurgia , Acetábulo/lesões , Fraturas do Quadril/cirurgia , Placas Ósseas
15.
Int Orthop ; 48(5): 1241-1247, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38499712

RESUMO

PURPOSE: The aims of this study were to evaluate the survivorships of a new generation cementless DMC with tripod additional fixation in revision total hip arthroplasty and complications at a minimum five year follow-up. METHODS: One hundred and fifteen revisions (THA) treated with tripod DMC performed between 2009 and 2015 were included in this retrospective study. Acetabular defects were classified as Paprosky 1 (n = 38, 33%), 2 (n = 75, 65%) or 3 (n = 2, 2%). Unipolar or bipolar revision was performed for the following indications: aseptic acetabular loosening (63%), infection (14%), aseptic bipolar loosening (11%), instability (4%), aseptic femoral loosening (3%), ALVAL (3%) and iliopsoas impingement (2%). Mean follow-up was 9.4 years ± two (range, 5 to 14). RESULTS: At the final follow-up, a single episode of dislocation occurred within three months after the procedure (0.8%) with no revision. Three cases of aseptic loosening were diagnosed (2.6%). Four infections (3.5%) required reoperation: three required a two stage bipolar revision; one was treated by DAIR procedure. At the latest follow-up, the survivorship of the acetabular cup for aseptic loosening was 98% [95% CI (91.2-99.4)] and for any reasons was 94.4% [95% CI (90.1%-98.9%)]; the mean HHS improved from 60 points (range, 18-94 points) to 83 points (range, 37-100 points) (p < .001). CONCLUSION: This study reports a low complication rate in favour of the use of a tripod DMC in revision THA with a satisfactory survivorship at a ten year follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
16.
Bone Joint J ; 106-B(4): 336-343, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555935

RESUMO

Aims: Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve. Methods: The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time. Results: The learning curve in this series was 26 PAOs in a period of six months. After 26 PAO procedures, a significant drop in surgical time was observed and a plateau was also achieved. The mean duration of surgery during the learning curve was 103.8 minutes (SD 33.2), and 69.7 minutes (SD 18.6) thereafter (p < 0.001). Radiological correction of acetabular retroversion showed a significant improvement after having performed a total of 93 PAOs, including anteverting PAOs on 35 hips with a retroverted acetabular morphology (p = 0.005). Several factors were identified as independent variables influencing duration of surgery, including patient weight (ß = 0.5 (95% confidence interval (CI) 0.2 to 0.7); p < 0.001), learning curve procedure phase of 26 procedures (ß = 34.0 (95% CI 24.3 to 43.8); p < 0.001), and the degree of lateral correction expressed as the change in the lateral centre-edge angle (ß = 0.7 (95% CI 0.001 to 1.3); p = 0.048). Conclusion: The learning curve for PAO surgery requires extensive surgical training at a high-volume centre, with a minimum of 50 PAOs per surgeon per year. This study defined a cut-off value of 26 PAO procedures, after which a significant drop in surgical duration occurred. Furthermore, it was observed that a retroverted morphology of the acetabulum required a greater number of procedures to acquire proficiency in consistently eliminating the crossover sign. These findings are relevant for fellows and fellowship programme directors in establishing the extent of training required to impart competence in PAO.


Assuntos
Luxação do Quadril , Articulação do Quadril , Humanos , Masculino , Feminino , Articulação do Quadril/cirurgia , Luxação do Quadril/cirurgia , Curva de Aprendizado , Estudos Retrospectivos , Resultado do Tratamento , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Osteotomia/métodos
17.
Bone Joint J ; 106-B(4): 352-358, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555941

RESUMO

Aims: Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods: We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results: There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion: While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Feminino , Idoso , Masculino , Falha de Prótese , Desenho de Prótese , Estudos Retrospectivos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxações Articulares/cirurgia , Reoperação/métodos , Seguimentos
18.
Bone Joint J ; 106-B(4): 312-318, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555951

RESUMO

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.


Assuntos
Artroplastia de Quadril , Doenças Ósseas Metabólicas , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Porosidade , Acetábulo/cirurgia , Reoperação , Metais , Falha de Prótese , Estudos Retrospectivos , Seguimentos
19.
Bone Joint J ; 106-B(4): 359-364, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555950

RESUMO

Aims: To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods: We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results: The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion: There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Idoso , Estudos Prospectivos , Reoperação , Desenho de Prótese , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Falha de Prótese , Seguimentos
20.
BMC Musculoskelet Disord ; 25(1): 242, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539141

RESUMO

PURPOSE: The results after acetabular fracture are primarily related to the quality of articular reduction. Using the AO large femoral distractor, incarcerated fragments can be easily removed, and marginally impacted fragments can be elevated under direct visualization without further re-dislocating the joint. The current study aimed to evaluate our early results of using the AO large femoral distractor as an assisting tool during ORIF of acetabular fractures associated with marginal impaction or intraarticular incarcerated fragments. METHODS: Eighteen patients were included in this retrospective case series study diagnosed with an acetabular fracture associated with either marginal impaction injury or an intraarticular incarcerated fragment. On a usual operative table, all patients were operated upon in a prone position through the Kocher Langenbeck approach. The AO large femoral distractor was used to facilitate hip joint distraction. Postoperative fracture reduction and joint clearance were assessed in the immediate postoperative CT scans. RESULTS: The average age of the patients was 30 ± 8.2 years; 13 (72.2%) were males. All cases had a posterior wall fracture, and it was associated with transverse fractures, posterior column fractures, and T-type fractures in five (27.8%), two (11.1%), and one (5.6%) patients, respectively. Intraarticular incarcerated fragments were present in 13 (72.2%) cases and marginal impaction in five (27.8%). Fracture reduction measured on the postoperative CT scans showed an anatomical reduction in 14 (77.8%) patients, imperfect in four (22.2%), and complete clearance of the hip joint of any incarcerated fragments. CONCLUSION: The use of the AO large femoral distractor is a reliable and reproducible technique that can be applied to assist in the removal of incarcerated intraarticular fragments and to ease the reduction of marginally impacted injuries associated with acetabular fractures.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Prisioneiros , Fraturas da Coluna Vertebral , Masculino , Humanos , Adulto Jovem , Adulto , Feminino , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões , Estudos Retrospectivos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Fraturas do Quadril/complicações , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas da Coluna Vertebral/complicações , Fixação Interna de Fraturas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...